Fronius IG4000 Inverter, 240V, 4000 Watts |
||
|
|
||
| Price:
$2,935.00
|
||
GRID-TIED INVERTERS FOR PHOTOVOLTAIC SYSTEMS Light Weight At 42 lbs, the FRONIUS IG inverters are the lightest grid-connected inverters making them both easy and cost-effective to install.More Energy MIXTM Concept allows your system to output more energy under part-load conditions.Lower Cost Integrated UL approved DC & AC disconnects which reduce installation time and complexity - often eliminating the need for additional disconnects.LCD Display User-friendly and comes standard with every FRONIUS IG; tracks more than 20 critical system performance parameters.Powerful At 4000, 4500 and 5100 watts, these inverters deliver more power output for higher performance installations.Reliable Fronius has been in business for over 60 years and has more than 200,000 FRONIUS IG inverters installed worldwide.Warranty 10 year Premium Warranty.DC Input Powe FRONIUS IG 4000 FRONIUS IG 5100 FRONIUS IG 4500 LV Recommended PV power 3000 – 5000 Wp 4000 – 6300 Wp 3600 – 5500 Wp Max. DC input voltage 500 V 500 V 500 V Operating DC voltage range 150 – 450 V 150 – 450 V 150 – 450 V Max. usable DC input current 26.1 A 33.2 A 29.3 A AC Output Data FRONIUS IG 4000 FRONIUS IG 5100 FRONIUS IG 4500-LV Maximum output power @40° C 4000 W 5100 W 4500 W Nominal AC output voltage 240 V 240 V 208 V Utility AC voltage range 212 – 264 V (240 V +10% / -12%) 183 – 227 V Maximum AC current 16.7 A 21.3 A 21.6 A Maximum utility back feed current 0.0 A 0.0 A 0.0 A Operating frequency range 59.3 – 60.5 Hz (60 Hz nom) Total harmonic distortion < 5 % Power Factor (cos phi) 1 General Data FRONIUS IG 4000 FRONIUS IG 5100 FRONIUS IG 4500-LV Max. efficiency 95.2 % 95.2 % 94.4 % Consumption in stand-by < 0.15 W (night) Consumption during operation 15 W Enclosure NEMA 3R Size (l x w x h) 28.4 x 16.5 x 8.8 in (720 x 418 x 223 mm) Weight 42 lbs. (19 kg) Ambient temperature range -5 to 122 °F (-20 to +50 °C) Cooling controlled forced ventilation Integrated DC and AC disconnects standard UL approved DC & AC disconnects Protections Ground fault protection Internal GFDI, in accordance with UL 1741 DC reverse polarity protection Internal diode Islanding protection Internal, in accordance with UL 1741, IEEE 1547 Over temperature Output power derating Surge Protection Internal DC & AC protection, Tested to 6 kV Compliance Safety UL 1741 EMI FCC Part 15; Class A & B Anti-Islanding protection UL 1741, IEEE 1547 Ground fault detector and interrupter Compliant with NEC Art. 690 requirements, UL 1741 Miscellaneous Maximum AC over current protection Two-pole, 30 A circuit breaker AC wire sizing Use maximum AWG 6 194°F (90 °C) copper wire DC wire sizing Use maximum AWG 6 194°F (90 °C) copper wire AC disconnect 32 A DC disconnect 40 A Warranty 10 year Premium Warranty is Standard |
||
Last Updated:
